IMPRESSION - A randomised trial to evaluate the efficacy of MagicTouch Sirolimus Coated Balloon in Dysfunctional Fistula progresses rapidly

By ANI | Published: June 23, 2021 04:55 PM2021-06-23T16:55:46+5:302021-06-23T17:05:07+5:30

Concept Medical Inc., focused on vascular intervention drug delivery devices, has updated the progress of IMPRESSION (sIroliMus coated balloon angioPlasty versus plain balloon angioplasty in the tREatment of dialySis acceSs dysfunctION) randomised trial.

IMPRESSION - A randomised trial to evaluate the efficacy of MagicTouch Sirolimus Coated Balloon in Dysfunctional Fistula progresses rapidly | IMPRESSION - A randomised trial to evaluate the efficacy of MagicTouch Sirolimus Coated Balloon in Dysfunctional Fistula progresses rapidly

IMPRESSION - A randomised trial to evaluate the efficacy of MagicTouch Sirolimus Coated Balloon in Dysfunctional Fistula progresses rapidly

, focused on vascular intervention drug delivery devices, has updated the progress of (sIroliMus coated balloon angioPlasty versus plain balloon angioplasty in the tREatment of dialySis acceSs dysfunctION) randomised trial.

is a prospective, multi-center, two-arm parallel group, randomised clinical trial to compare the efficacy of Sirolimus Coated Balloon versus Placebo Plain Balloon (control arm) in the treatment of dysfunctional (stenosed) fistula used for vascular access in hemodialysis. A total of 170 patients with End Stage Renal Disease (ESRD) are being randomised in 1:1 fashion (: Placebo Plain Balloon).

The study's primary objective is to determine if the use of Sirolimus Coated Balloon will result in an improvement of the primary circuit patency at six months when compared head-to-head with plain balloon angioplasty (POBA).

The Sirolimus Coated Balloon has already been granted the Breakthrough Device Designation by the U.S. Food and Drug Administration (FDA). Only ESRD patients with a matured dysfunctional arterio-venous fistula (AVF) that has been in use for at least one month prior to angioplasty will be enrolled.

The study is being conducted at three sites in Singapore led by Associate Professor Chieh Suai Tan, Head and Senior Consultant, Department of Renal Medicine, Singapore General Hospital (SGH), as the principal investigator. Other site principal investigators include Associate Professor Edward Choke, Senior Consultant, Department of Surgery, Sengkang General Hospital, and Associate Professor Jackie Ho, Senior Consultant, Department of Cardiac, Thoracic and Vascular Surgery, National University Heart Centre, Singapore. The index patient was enrolled on 11th January 2021 and at the time of going to press, 37 patients have been enrolled.

SGH was chosen to lead this randomised controlled trial because of its prior experience using Sirolimus Coated Balloon in two investigator-initiated pilot studies. The studies had shown that patency rates with the use of in thrombosed arterio-venous graft (AVG) and dysfunctional AVF were 65 per cent and 82.9 per cent at six months, respectively.

An operational vascular access such as AVF or (AVG) is vital in ESRD patients for effective and long-term hemodialysis. Unfortunately, due to various reasons, the AVF or AVG may narrow (stenosis), resulting in poor flow of the vascular access, which affects hemodialysis. The functional life of an AVF is poor with as high as 50 per cent chance of failure after a median of three to seven years.

Singapore has one of the highest ESRD incident rates globally. POBA is the current standard treatment for patients with AVF stenosis. Despite the minimally invasive nature of POBA procedure, the long-term patency is poor, averaging 40 to 50 per cent at one year. This necessitates multiple procedures in order to maintain patency of the vascular access.

Paclitaxel Coated Balloon is also being used to treat dysfunctional AVF with mixed success. However, the safety concerns of Paclitaxel raised by the U.S. FDA and the issue of guidelines by the interventional societies have prompted doctors to seek a better alternative.

This story is provided by PRNewswire.will not be responsible in any way for the content of this article. (ANI/PRNewswire)

( With inputs from ANI )

Disclaimer: This post has been auto-published from an agency feed without any modifications to the text and has not been reviewed by an editor